1220L PV High Humidity And Temperature Controlled Chamber IEC62108
Product Details:
Place of Origin: | China |
Brand Name: | LIB |
Certification: | CE,ROHS |
Model Number: | PV-04 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 Set |
---|---|
Packaging Details: | Wooden Cases Standard Export Package |
Delivery Time: | 5-14 Days |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram,Paypal |
Supply Ability: | 210 Sets/quarter |
Detail Information |
|||
Application: | PV Panel | Panel Capacity: | 4 / 6 / 8 / 10 / 12 Pieces |
---|---|---|---|
Standard: | IEC61215, IEC61646, IEC61108, IEC62688, UL1703, IEC61345 | Temperature Range: | -70 Degree ~ +100(150) Degree |
Temperature Range: | -60℃ ~ +100 ℃ | Temperature Change Rate: | 1 ~ 3.4℃ / Min |
High Light: | 1220L Humidity And Temperature Controlled Chamber,IEC62108 Humidity And Temperature Controlled Chamber,1220 Liter constant climate chamber |
Product Description
Description
IEC62108 85℃ PV High Humidity Temperature Chamber with uncompromised features at competitive prices. Ideal for choosing your best suit for variable sizes of Solar Panels and PV Modules from the available range of standard and Custom-Built Chambers. High performance & inherent reliability guaranteed for continuous testing of your products
Technical Specification
Name | IEC62108 85℃ PV High Humidity Temperature Chamber |
Model | PV-04 |
Internal Dimension (mm) |
1300*700*1350 |
Overall Dimension (mm) |
1900*1100*1750 |
Interior Volume |
1220L |
Temperature Range |
-60℃ ~ +100 ℃ |
Temperature Fluctuation |
± 0.5 ℃ |
Temperature Deviation |
± 2.0 ℃ |
Humidity Range |
20% ~ 98% RH |
Humidity Deviation |
± 2.5% RH |
Temperature Change Rate |
1 ~ 3.4℃ / Min |
Panel Size |
1M*2M |
Panel Capacity |
4 / 6 / 8 / 10 / 12 Pieces |
Cooling system |
Mechanical compression refrigeration system |
Refrigerating unit |
French TECUMSEH compressor |
Refrigerant |
R404A, R23 |
Heating Element |
Nichrome heater |
Controller |
Programmable color LCD touch screen controller,Ethernet connection, PC Link, USB |
Exterior Material |
Steel Plate with protective coating |
Interior Material |
SUS304 Stainless steel |
Thermal Insulation |
Polyurethane foam and insulation cotton |
Maximum Noise |
65 dBA |
Environmental Conditional |
5℃~+35 ℃ ≤85% RH |
Standard |
IEC61215, IEC61646, IEC61108, IEC62688, UL1703, IEC61345 |
![]() |
Environmental Test Chambers for Solar Panels |
Test Purpose
IEC62108 85℃ PV High Humidity Temperature Chamber
To identify the ability of components to withstand long-term moisture penetration
Test Procedure
IEC62108 85℃ PV High Humidity Temperature Chamber
A) pretreatment
Will be at room temperature without pretreatment of components in the air.
B) Strict conditions
Test temperature: 85 ℃ + 2 ℃
Relative humidity: 85% ± 5%
Test time: 1000 h
PV Test Cycle
Thermal Cycle Test
Damp Heat Test
Humidity Freeze Test