Low Temperature Damp Heat Humidity Test Chamber Weather Resistance
Product Details:
Place of Origin: | China |
Brand Name: | LIB |
Certification: | CE,RoHS |
Model Number: | TH-225 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 Set |
---|---|
Packaging Details: | Wooden Box standard export package |
Delivery Time: | 3-14 days |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, paypal,MoneyGram, |
Supply Ability: | 180 sets / quarter |
Detail Information |
|||
Name: | -60℃ Low Temperature Damp Heat Chamber | Low Type: | -20℃/-40℃/-60℃/-70℃/-86℃ |
---|---|---|---|
Controller: | PLC,PC Link, R-232 Interface,USB,APP | Humidity Range: | 10% - 98% RH |
Temperature Range: | -20℃ ~+150 ℃ | Exterior Material: | A3 Steel Plate |
High Light: | Damp Heat Humidity Test Chamber,A3 Steel Plate Humidity Test Chamber,Programmable LCD Humidity Test Chamber |
Product Description
-60℃ Low Temperature Damp Heat Chamber
Description
-60℃ Low Temperature Damp Heat Chamber simulates the temperature and humidity changes in natural weather, and can also realize extreme high temperature and low-temperature scenarios, and conduct high temperature, low temperature, wet and dry weather resistance tests on the test items.
Main Technical Parameter
Name |
-60℃ Low Temperature Damp Heat Chamber |
Model |
TH-225 |
Internal Dimension (mm) |
500*600*750 |
Overall Dimension (mm) |
960*1150*1860 |
Temperature Range (℃) |
A: -20℃ ~+150 ℃ B:-40℃ ~+150 ℃ C:-70℃ ~+150 ℃ |
Humidity Range (R.H) |
20% ~ 98% RH |
Temperature fluctuations |
± 0.5 ℃ |
Temperature deviation |
± 2.0 ℃ |
Humidity Deviation |
± 2.5% RH |
Heating Rate |
3 ℃ / min |
Cooling Rate |
1 ℃ / min |
Interior Volume |
500 liters |
Controller |
Programmable color LCD touch screen controller, Multi-language interface, Ethernet , USB |
Cooling System |
Mechanical compression refrigeration system |
Interior Material |
SUS304 stainless steel |
Maximum Noise |
65 dBA |
Power Supply |
380V |
Deatil
Programmable Controller
|
Water Circulation System |
The working temperature and humidity of the -60℃ Low Temperature Damp Heat Chamber are: ambient temperature: 5℃~+30℃ (average temperature within 24 hours ≤30℃), ambient humidity: ≤85%RH.
Application
After the test items undergo temperature changes and changes in air humidity in nature, some aging phenomena will occur, which may affect the performance of the items.
The constant Heat Chamber is used to simulate this environment to accelerate the results of the items.